Page 28 of 56
Time - the amount of time that elapse before the system reboots. NB!
If this is set as the first action on an input you will not be able to set a
second action.
4. Pulse Relay - when you select pulse relay as an action there are two
parameters that need to be set.
Relay - the relay that you want to pulse.
Seconds - the duration in seconds that the relay must pulse.
5. Make Call - when you select make call as an action there are two parameters
that need to be set.
(Number) the number that the MKII must call.
Cut off time in sec - the amount of time that MKII allows the call to
continue before cutting off the call.
6. Server Connection - when you select server connection as an action there is
only one parameter that needs to be set.
Time - The time in seconds that must elapse before a connection
must be made. NB! If this is set as the first action on an input you will
not be able to set a second action.
7. Log -when you select log as an action there is only one parameter that needs
to be set.
Message - This is the message that will show on the report of the MKII. This
option is mainly used as a reporting
ADD A NEW INTERCOM
Click on the Intercom Top menu, the context window will display your current
intercoms. The left tab menus are Gate trigger defaults, Time grids, PC Boards and
Add new intercom. Click on the add new intercom. There are ten (10) different
headings namely, Name, Volumes, Ring Call Times, Alternative Phone Numbers,
Incoming Calls, Relays, Sim information, SMS Group, Inputs and PC Board. Refer to
How to configure an intercom for instructions. Once done click save. The new
intercom will now display in a left tab menu.
Commentaires sur ces manuels